Advanced Ultrasound in Diagnosis and Therapy ›› 2026, Vol. 10 ›› Issue (3): 169-177.doi: 10.26599/AUDT.2026.250086

• ORIGINAL RESEARCH • Previous Articles     Next Articles

3D Dynamic Contrast-Enhanced Ultrasound for Personalized RRx-001 Dosing: A Preclinical and Clinical Pilot Study

Oronsky Bryana, Li Dandanb, Wang Morganb, Vo-Phamhi Jenny M.c,d, Caroen Scotta, Abrouk Nacera, Reid Tonya, Alizadeh Babaka, Hristov Dimitree, Fisher Georgef, Kaffas Ahmed Elg,*()   

  1. aEpicentRX, La Jolla, CA
    bDepartment of Radiology, Stanford University, Stanford, CA, USA
    cVagelos College of Physicians & Surgeons, Columbia University, New York, NY, USA
    dAlta Bates Summit Medical Center, Oakland, CA, USA
    eDepartment of Radiation Oncology, Stanford University, Stanford, CA, USA
    fDepartment of Medicine, Stanford University, Stanford, CA, USA
    gDepartment of Radiology, University of California, San Diego, La Jolla, CA, USA
  • Received:2025-08-09 Revised:2025-08-20 Accepted:2025-12-08 Online:2026-09-30 Published:2026-10-12
  • Contact: Kaffas Ahmed El, E-mail:aelkaffas@health.ucsd.edu

Abstract:

Background and Purpose Tumor blood vessels are abnormal and contribute to therapy resistance. RRx-001, an NLRP3 inhibitor, has been shown to remodel tumor vascular properties, enhancing the effects of cytotoxic or immune-promoting agents. However, optimizing timing and dosing of combined treatment regimens is challenging on a patient-by-patient basis; tools for longitudinal imaging to guide such treatment strategy are necessary. Our aim was to evaluate the feasibility of 3D dynamic contrast-enhanced ultrasound (3D DCE-US) to detect acute and subtle tumor perfusion changes following RRx-001 therapy in both mice and humans.
Methods RRx-001 was administered intraperitoneally at varying doses to determine its effect on perfusion in a mouse model of colon cancer. Blood flow and volume were assessed semi-quantitatively using 3D DCE-US within hours and at subsequent time-points. Additionally, we assessed 3D DCE-US in three patients enrolled in a Phase 2 RRx-001 clinical trial (NCT02096354) by imaging them longitudinally.
Results In mice (n = 38), 6 mg/kg RRx-001 led to a 1.5% increase in AUC (P = 0.02) and MTT at 24 hours; 12 mg/kg showed no acute effect. In patients (n = 3), 66 mg weekly dosing produced variable perfusion changes within hours to days. Two patients with stable disease showed transient perfusion increases (survival 9-15 months); one with progressive disease showed early perfusion loss (survival 4 months). No grade 3/4 toxicities occurred.
Conclusion These findings highlight the potential of 3D DCE-US as a noninvasive, bedside tool for real-time monitoring of RRx-001-induced perfusion changes, supporting the feasibility of personalized dosing strategies in both preclinical and clinical settings.

Key words: Ultrasound; Vascular normalization; Contrast-enhanced ultrasound; Oncology; Tumor vasculature